<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22353</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: "Conveyor exit is blocked"
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check sensor.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Remove plate on conveyor exit sensor, Resume.
Reset machine.
</text></DescriptionText>
</OperatorAction>
<Cause>
Exit sensor detects an object when no plate is expected to be
there.
- Before plate can be ejected off the table, the conveyor must be clear.
- If exit sensor is blocked while waiting for plate to arrive.
- For L conveyor, if exit sensor remains blocked after timeout (240 seconds) waiting for
plate to leave conveyor.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/conv.xml</LinkAddress><LinkTitle>Command: conv</LinkTitle></Link>
<Link><LinkAddress>../nvs/val_cfg_cvsens.xml</LinkAddress><LinkTitle>NVS: val cvsens</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:07 2008 PST
</Updated>